Shell and Tube HEX
[열교환기] Baffle Spacing에 대한 TEMA 요구사항
기계엔지니어
2021. 4. 26. 08:11
반응형
S&T Heat Exchanger의 Baffle Spacing을 결정하기 위한 요구사항 (TEMA)
- TEMA RCB-4.51 : ID의 1/5 및 51mm 보다 커야 한다.
- TEMA RCB-4.52 : unsupported tube 길이는 Table에 표기된 값보다 커서는 안된다. 이점을 고려하여 Baffle Spacing을 정해야 한다..
(TEMA) RCB-4.51
RCB4.5 SPACING OF BAFFLES AND SUPPORT PLATES
RCB4.51 MINIMUM SPACING
Segmental baffles normally should not be spaced closer than 1/5 of the shell ID or 2 in. (51
mm), whichever is greater. However, special design considerations may dictate a closer
spacing.
(TEMA) RCB-4.52
RCB-4.52 MAXIMUM SPACING
Tube support plates shall be so spaced that the unsupported tube span does not exceed
the value indicated in Table RCB-4.52 for the tube material used.
반응형