본문 바로가기

Shell and Tube HEX

[열교환기] Tube Projection에 대한 API660 및 TEMA 요구사항

반응형

Tube Joint 결정을 위한 요구사항 (API 660, TEMA)

 

API 660 9.10.7Tube Tubesheet Face에서 5mm 이하로 Extened 되어야 한다. ( Vertical Type은 예외)

TEMA RCB-7.313에 따르면 Tube Diameter1/2 이상이 Extend 되면 안된다. ( Vertical Type은 예외)

 

 

1. (API 660) 9.10.7

Tubes shall be flush with or extended by no more than 5 mm (3/16 in.) beyond the face of the tubesheet, except in vertical exchangers when tubes shall be flush with the top tubesheet, unless otherwise specified by the purchaser.

 

 

2. (TEMA) RCB-7.313

RCB-7.313 TUBE PROJECTION

Tubes shall be flush with or extend by no more than one half of a tube diameter beyond the

face of each tubesheet, except that tubes shall be flush with the top tubesheet in vertical

exchangers to facilitate drainage unless otherwise specified by the purchaser.

 

 

반응형